Flue Vent 185mm – Terracotta Pepper Pot Flue Terminal

£65.45 ex. VAT

8 in stock

15 People watching this product now!
14 Items sold in last 3 hours

Description

  • 185 mm spigot diameter – designed to fit inside the opening of a suitable existing chimney pot.
  • 🏗️ Traditional terracotta clay pepper pot for redundant and disused chimney flues.
  • 🌬️ Promotes natural ventilation to help reduce condensation, damp and stale odours within the chimney.
  • ⚒️ Simple mortar-bed installation into an existing chimney pot using external-grade mortar.
  • 🚚 Fast UK delivery with expert advice from Chimney Cowls UK.
The Ultimate Guide

How To Install A Chimney Cowl

Get a step by step on how to install your chimney cowl

Weight 8 kg
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Flue Vent 185mm – Terracotta Pepper Pot Flue Terminal”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.

We advise that your chimney or flue is inspected and swept by a qualified chimney sweep before fitting a chimney cowl or terminal. We also recommend using a professional to specify the correct product for your fuel, chimney system, size and needs. 

⚠️We cannot take responsibility for any terminal or cowl that has not been specified or fitted by a professional and is not suitable for your application.

Description
HOT BOX COWLS · KYL12 · REDUNDANT FLUE TERMINAL

KYL12 Pepper Pot Flue Terminal — 185mm Spigot, Terracotta Clay

A traditional terracotta clay pepper pot terminal designed to ventilate redundant and disused chimney flues while helping reduce direct rain entry at the top of the chimney.

IMPORTANT SIZE 185 mm outside-diameter spigot The lower spigot is designed to sit inside the opening of the existing chimney pot.

Before ordering, measure the internal diameter of the opening at the top of your existing chimney pot and confirm that it can accommodate the approximately 185 mm outside-diameter spigot.

Vent, don’t seal — keep the redundant chimney breathing.

01

Why choose the KYL12 terracotta pepper pot?

Traditional clay appearance, straightforward fitment and controlled ventilation for redundant chimney flues.

Ø
185 mm external spigot

The lower insert section has an approximately 185 mm outside diameter.

Promotes ventilation

Allows a redundant or disused chimney to remain ventilated rather than being completely sealed.

Traditional terracotta

A classic clay appearance suited to traditional, period and heritage-style properties.

Covered terminal

The pepper pot profile helps reduce direct rain entry while retaining ventilation.

Mortar-bed fitting

The lower spigot is inserted into the existing chimney pot and securely bedded and pointed as appropriate.

!
Redundant flues only

This product is not intended as the terminal for a working fire, stove, gas appliance or oil appliance.

02

185 mm spigot size — what should I measure?

Correctly measuring the existing chimney pot is the most important step before ordering.

WHAT TO MEASURE
  1. Measure the internal diameter of the opening at the top of your existing chimney pot.
  2. Confirm that the opening can accommodate an approximately 185 mm outside-diameter spigot.
  3. If the pot is tapered, irregular or weathered, measure the opening in more than one direction.
  4. Do not rely solely on nominal descriptions such as 7″, 7.5″ or 8″. Clay chimney pots can vary in their actual internal dimensions.
03

KYL12 technical specification

Key dimensions and application information for this terracotta pepper pot flue terminal.

Internal base 150 mm
External spigot 185 mm
Top diameter 300 mm
Overall height 200 mm
Model KYL12
Product type Terracotta clay chimney terminal / pepper pot
Internal base diameter Approx. 150 mm
External spigot diameter Approx. 185 mm
Top diameter Approx. 300 mm
Overall height Approx. 200 mm
Spigot position Lower cylindrical section designed to insert inside the existing chimney pot opening
Measurement required Internal diameter of the opening at the top of the existing chimney pot
Colour Terracotta
Material Fired clay / terracotta
Application Ventilation and weather protection of redundant or disused chimney flues
Live appliance use No — select a suitable appliance-specific chimney terminal or cowl for a live flue
Installation Insert the lower spigot into the existing chimney pot and securely bed and point as appropriate

Looking for related components? See pepper pot inserts at The Reclaimed Company .

04

When should this pepper pot be used?

The KYL12 is designed specifically for redundant and disused chimney flues.

SUITABLE FOR
  • Redundant chimney flues
  • Disused fireplaces
  • Chimneys where continued ventilation is required
  • Traditional clay terminal applications
  • Helping reduce direct rain entry while retaining airflow
NOT FOR
  • Wood-burning stoves
  • Multifuel stoves
  • Working open fires
  • Gas appliances
  • Oil appliances

For active flues, compare chimney cowls at Hot Box Stoves . You can also read Chimney Caps vs Chimney Cowls .

05

Installation guidance

Straightforward fitting principles for installation into a suitable redundant chimney pot.

01 Confirm the flue is redundant

Ensure that the chimney is not serving a working combustion appliance.

02 Measure the pot opening

Measure the internal diameter and confirm that the approximately 185 mm external spigot can be accommodated.

03 Check the chimney condition

Check that the chimney pot, flaunching, stack and surrounding masonry are secure and suitable for installation.

04 Insert the spigot

Position the lower section of the terminal inside the opening of the existing chimney pot.

05 Bed and point

Secure using suitable external-grade mortar and finish neatly around the junction.

06 Keep ventilation clear

Ensure the ventilation openings remain unobstructed and retain appropriate low-level ventilation to the redundant flue.

INSTALLATION & COMPLIANCE NOTE

For redundant stacks, controlled ventilation is generally preferable to completely sealing the flue. A chimney serving a working combustion appliance requires a terminal appropriate to the appliance, fuel and chimney system.

General UK guidance relating to chimneys, flues and combustion appliances can be found in Approved Document J . Listed buildings and properties in conservation areas may also require chimney terminals and external alterations that are sympathetic to the character of the building.

Chimney-level work involves significant work-at-height risks and should only be undertaken using appropriate access and safety arrangements.

06

Frequently asked questions

Common questions about KYL12 sizing, suitability and installation.

What does the 185 mm measurement refer to?

The 185 mm measurement is the approximate outside diameter of the lower spigot. This is the section of the pepper pot terminal designed to insert inside the opening of the existing chimney pot.

What is the internal diameter of the KYL12?

The KYL12 has an approximately 150 mm internal base diameter and an approximately 185 mm external spigot diameter.

Is 185 mm the size of the chimney pot or the flue?

Neither. The 185 mm dimension describes the outside diameter of the lower insert spigot. Measure the internal diameter of your existing chimney pot opening to determine whether the terminal will fit.

Should I measure the inside or outside of my chimney pot?

Measure the inside diameter of the opening at the top of the existing chimney pot. This is the opening into which the approximately 185 mm external spigot is inserted.

My chimney pot is described as 7 inches. Will the KYL12 fit?

Do not order solely from a nominal 7″, 7.5″ or 8″ description. Clay chimney pots can vary in wall thickness, taper and actual internal dimensions. Measure the actual internal opening and compare it with the approximately 185 mm external spigot before ordering.

How large is the top of the pepper pot?

The KYL12 has an approximately 300 mm top diameter and an approximately 200 mm overall height.

Can this terminal be used on a working fire or wood-burning stove?

No. The KYL12 pepper pot is intended for redundant or disused flues. A working stove, open fire or other combustion appliance requires a terminal or chimney cowl suitable for the particular appliance, fuel and flue system.

Does a redundant chimney need ventilation?

In many situations it is beneficial to retain controlled ventilation through a redundant flue rather than completely sealing it. Ventilation can help disperse moisture, condensation and stale air within the chimney.

Will the pepper pot keep all rain out?

The covered profile helps reduce direct rainfall entering the chimney while retaining ventilation. It should not be regarded as creating a completely watertight seal.

What if my chimney pot opening is only slightly larger than 185 mm?

Measure carefully before ordering. The existing opening must be sufficiently large for the approximately 185 mm outside-diameter spigot to enter and for the terminal to be installed securely.

KYL12 · READY TO ORDER?

185 mm Spigot Terracotta Pepper Pot

Check before buying: confirm that the internal opening of your existing chimney pot can accommodate an approximately 185 mm outside-diameter spigot.

Add to basket
✓ Fast UK delivery ✓ Expert product advice ✓ Traditional terracotta clay
Additional information
Weight 8 kg
Shipping & Delivery
⚠️Important

We advise that your chimney or flue is inspected and swept by a qualified chimney sweep before fitting a chimney cowl or terminal. We also recommend using a professional to specify the correct product for your fuel, chimney system, size and needs. 

⚠️We cannot take responsibility for any terminal or cowl that has not been specified or fitted by a professional and is not suitable for your application.